Stealth power source for defence & security applications

Without power you are nothing!

Electricity has become an indispensable element in modern military operations. Electrically-powered systems are now fundamental to both defensive and offensive capabilities, supporting everything from advanced communication networks and surveillance systems to precision weaponry.

Byproducts for current electric generators are heat and noise. A deadly combination on the battlefield.

Communications

Military drones

Ground operations

Remote radar stations

Operation centers

Field hospitals

Soldier camps

Other devices

Tested on the Field by NATO forces

Tested by NATO Energy Security Centre

Received "highly recommended" credits

Tested for portability, stealth, resilience and field capabilities

Tested for a variety of different applications during military exercises, including in NATO’s largest exercise, Steadfast Defender 2024, with 90,000+ troops from all 32 NATO Allies

Different systems deployed

For ground combat, mobile equipment, and off-grid military infrastructure

Diesel requires replacement every 6–12 months, and stored drums take up significant space and demand constant monitoring. Additionally, batteries gradually lose stored energy over time due to climate conditions, while also providing a relatively lower power output for their size.

UP400

First Step in Energy
Independence

UP400 is a perfect starting point for off-grid power needs, and it allows full grid independence when connected to solar panels, wind turbines, or even your electrolyser.

 

Nominal power output 400 W
Nominal output voltage 12/24 V
Current at 24 V 34.7 A
Fuel Compressed hydrogen (>99.97%)
Fuel consumption at max power 5.2 normal l/min (26 g/hour)
Dimensions (L × W × H) 700 × 222 × 312 mm
Weight 21 kg
Operating ambient temperature -5 °C to 40 °C
Noise level 45 dB

UP1K

Reliable Backup Power for Critical Needs

This 1kW generator is an ideal solution for disaster relief or powering tools in the construction or defence sector. Pair it with batteries, solar panels, or wind turbines for a smart microgrid.

 

Nominal power output 1000 W
Nominal output voltage 12/24 V
Current at 24 V 41.7 A
Fuel Compressed hydrogen (>99.97%)
Fuel consumption at max power 13 normal l/min (65 g/hour)
Dimensions (L × W × H) 700 × 222 × 410 mm
Weight 27 kg
Operating ambient temperature -5 °C to 40 °C
Noise level 45 dB

UP3K

Reliable Backup Power for Critical Needs

The UP3K is a 3kW hydrogen fuel cell generator designed to meet the critical demands of the defense and security sector. Whether powering field operations, serving as a backup for command centers, or charging essential equipment, the UP3K ensures reliable energy in remote and high-stakes environments. Its modular design enables scalable power solutions, supporting both standalone and hybrid setups for maximum operational flexibility.

  • Grid drop detection
  • 5x I/O connections (3x dry contact detection, 2x programmable relays)
  • Remote monitoring and control
  • Different working modes (Battery mode, Generator mode)
  • Wide range of supported batteries
  • (Optional) 19” Rack solutions (Indoor/outdoor)
  • (Optional) Trailer-friendly mobile solution available (UPMobile)

Nominal power output
3K
6K
3000 W: 1 cell - Peak load 10 kw
6000 W: 2 cells - Peak load 10 kW
Output voltage 43V DC
System Voltage Customizable for 1-phase DC or AC or 3-phase AC
Power Distribution Customizable for 1-phase DC / AC
or 3-phase AC
Power Bank Options 3K 48 V / Minimum 200 Ah (10kwh)
6K 48 V / Minimum 200 Ah (10kwh)
Dimensions / Weight 3K 600 x 800 x 1600 mm / 200Kg
6K 600 x 800 x 2000 mm / 250Kg
IP class IP20
Features Service monitoring — IoT : Full system logs,
Remote monitoring and control — Start/Stop signal
Recommended temperature range -5°C to +40°C
Operating lifetime 10 000 hours

UPMobile

Reliable Hydrogen Power, Wherever You Go

UPMobile is available with either 3kW or 6kW of continuous fuel cell power. This versatile hydrogen fuel cell generator is an ideal solution for the military industry, ensuring uninterrupted access to power and other utilities to maintain readiness and critical services in tactical operation centers during missions. The powerful UPMobile boasts an external hydrogen supply for enhanced flexibility and can be easily transported on a trailer.

  • Screen
  • Service monitoring
  • IoT: Full system logs
  • Remote monitoring and control
  • Start/stop signal
System voltage (VDC) 42–75 VDC
Output voltage 42–75 V DC; 230 V AC (1P); 400 V AC (3P)
Output current (A) 0–300 A
Nominal power (kW) 10 kW (BOL) – 9 kW (EOL)
Rated power (kW) 15 kW (w/o battery)
FC peak power output (kW) 16.4 kW
Battery extender capacity (kWh) 6.8 kWh (1 module)
Battery extender peak power (kW) 34 kW (12 min – 5C)
Cooling system Deionized water (0.1 us/cm)
Fuel Compressed hydrogen (>99.97%)
Fuel consumption per kWh 60–73 g/kWh
Size (L × W × H) 1900 × 1500 × 1500 mm
Weight (kg) 220 kg
Start temperature (°C) > -10°C
Operating temperature (°C) from 5°C to 60°C
Operating hours (h) 20 000 h
IP rating IP54
Noise level 65 dB

Hydrogen safety and consumption

Safety is paramount at PowerUP, and to uphold this commitment, we've designed a specialized hydrogen safety system for our indoor fuel cell generators. This stand-alone system employs an off-the-shelf hydrogen sensor to detect leaks, automatically closing the valve to prevent further leakage until manual reset. With simplified implementation and user-friendly design, it ensures robust functionality and safety for fuel cell generators in rooms up to 60 m3. But it does not end there. Already during our production process we are using high quality 316 stainless steel tube and pipe fittings, assembled by skilled technicians to ensure maximum quality of the internal gas distribution system.

Multiple sensors and ATEX rated solenoids are securing leakage free operation and a safe handling of leaked hydrogen should it occur. With inner and outer safety regulated by different controllers we achieve maximum safety and redundancy.

PowerUP's products require pure hydrogen, demanding a purity level of ≥99.95% (Hydrogen 3.5 or higher). Impurities are tolerated within the limits of EN 17124. Maintaining high hydrogen purity is essential for achieving optimal performance, longevity, reliability, efficiency, and environmental benefits in our generators.

 

Different
cylinder options
1x26L
(300 bar)
50L
(200 bar)
2x50L
(200 bar)
12x50L
(200 bar)
  Kg of H2 in cylinders
0,573 0,736 1,471 8,828
Nominal power (W) Hours available
200 35 45 90 539
400 22 28 55 333
1000 9,2 11,9 23,7 142,4
3000 3,2 4,1 8,2 49

Get in touch